Meters | measuring principle | bar/psi | mm | % | % | Optional | Scope | Operation mode | ||||||||
PN min-max | DN min-max | Best Measuring Accuracy | Best Repeatability | build in T sensor | build in P sensor | bi directional | electronic totalizer | technological measurement | weights & measures approved measurement | max measuring range | max flow velocity (m/s) | installation V=vertical H=horizontal | Flow rate (m3/h) min / max | |||
Turbine | indirect | 10-250 | 25-600 | ± 0,5% | 0,1% | yes | yes | no | yes | yes | yes | 1:30 | 20 | V&H | 1/25000 | |
Positive Displacement | direct | 10-40 | 50-200 | ± 0,5% | 0,1% | yes | yes | no | yes | yes | yes | 1:160 | 20 | V&H | 1/1600 | |
Vortex | indirect | 10-100 | 25-600 | ± 0,5% | 0,1% | no | no | no | yes | yes | yes | 1:160 | 40 | V&H | 1/40000 | |
Coriolis | mass | 10-40 | 15-200 | ± 0,15% | 0,1% | yes | no | no | yes | yes | yes | 1:20 | V&H | 0/11400 | ||
Ultrasonic | indirect | 10-250 | 80-1000 | ± 0,15% | 0,1% | no | no | yes | yes | yes | yes | 1:120 | 40 | V&H | 3/110000 | |
Magnetic | mass | 10-600 | 25 - 2600 | ± 0,35% | 0,1% | no | no | yes | yes | yes | no | 1:20 | 10 | V&H | 0/191000 | |
Sonar | indirect | 50-1500 | 80 - 300 | ± 1% | 0.3% | no | no | yes | yes | yes | no | - | 10 | V&H | * | |
Differential Pressure Cone | indirect | 16-100 | 25 - 3000 | ± 0,5% | 0.1% | no | no | no | no | yes | yes | 1:30 | 20 | V&H | * | |
Differential Pressure Orifice | indirect | 16-250 | 50-600 | ± 0,5% | 0.1% | no | no | no | yes | yes | yes | 1:10 | 21 | V&H | * |