Meters measuring principle bar/psi mm % % Optional Scope Operation mode
PN min-max DN min-max Best Measuring Accuracy Best Repeatability build in T sensor build in P sensor bi directional electronic totalizer technological measurement weights & measures approved measurement max measuring range max flow velocity (m/s) installation V=vertical H=horizontal Flow rate (m3/h) min / max
Turbine indirect 10-250 25-600 ± 0,5% 0,1% yes yes no yes yes yes 1:30 20 V&H 1/25000
Positive Displacement direct 10-40 50-200 ± 0,5% 0,1% yes yes no yes yes yes 1:160 20 V&H 1/1600
Vortex indirect 10-100 25-600 ± 0,5% 0,1% no no no yes yes yes 1:160 40 V&H 1/40000
Coriolis mass 10-40 15-200 ± 0,15% 0,1% yes no no yes yes yes 1:20 V&H 0/11400
Ultrasonic indirect 10-250 80-1000 ± 0,15% 0,1% no no yes yes yes yes 1:120 40 V&H 3/110000
Magnetic mass 10-600 25 - 2600 ± 0,35% 0,1% no no yes yes yes no 1:20 10 V&H 0/191000
Sonar indirect 50-1500 80 - 300 ± 1% 0.3% no no yes yes yes no - 10 V&H *
Differential Pressure Cone indirect 16-100 25 - 3000 ± 0,5% 0.1% no no no no yes yes 1:30 20 V&H *
Differential Pressure Orifice indirect 16-250 50-600 ± 0,5% 0.1% no no no yes yes yes 1:10 21 V&H *